COMB GAS VALVE
Share
Product#HON V800A-1088
MPN V800A1088/U
UPC085267000710
Description
Used on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, pressure regulator, pilot gas filter and flow adjustment, pressure tapping and thermocouple connector.
Resideo Gas Valve, 1-Stage, Series: V800, 3/4 in Nominal, NPT, 0.5 psi, Standing Pilot Ignition, 34000 to 425000 Btu/hr Nominal Capacity, Natural Gas, 24 VAC 60 Hz Coil, 1/4 in Male Quick-Connect Terminal, 32 to 175 deg F, 4-3/4 in H x 4-1/16 in W x 3-3/16 in D, Import
Resideo Gas Valve, 1-Stage, Series: V800, 3/4 in Nominal, NPT, 0.5 psi, Standing Pilot Ignition, 34000 to 425000 Btu/hr Nominal Capacity, Natural Gas, 24 VAC 60 Hz Coil, 1/4 in Male Quick-Connect Terminal, 32 to 175 deg F, 4-3/4 in H x 4-1/16 in W x 3-3/16 in D, Import
COMB GAS VALVE
Share
Product#HON V800A-1088
MPN V800A1088/U
UPC085267000710
- Coil Voltage:Â 24 VAC 60 HzDimensions:Â 4-3/4 in H x 4-1/16 in W x 3-3/16 in DDomestic/Import:Â ImportElectrical Connections:Â 1/4 in Male Quick-Connect TerminalEnd Style:Â NPTGas Type:Â NaturalIgnition Type:Â Standing PilotNominal Capacity:Â 34000 to 425000 Btu/hrNominal Size:Â 3/4 inPressure Rating:Â 0.5 psiSeries:Â V800Temperature Rating:Â 32 to 175 deg FType:Â 1-Stage
- Easy to install, adjust and service, all adjustments and connections are accessible from top of control
- Add separate energy cutoff (ECO) where codes call for dual safety shutoff
- Complete safety shutoff on pilot flame failure
- Lite-Rite (Off-Pilot-On) lighting sequence
- ECO connector for V800 models part No 392451-1
- Body pattern - Straight-through, multi-tapped with 1/2 in right and left outlets plugged
- 0 to 90 deg in any direction from the upright position of the gas control knob mounting
- 3-1/2 in WC pressure regulator setting with 1/2 in side outlets
- Standard opening gas vavle
- Used on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, pressure regulator, pilot gas filter and flow adjustment, pressure tapping and thermocouple connector.
Resideo Gas Valve, 1-Stage, Series: V800, 3/4 in Nominal, NPT, 0.5 psi, Standing Pilot Ignition, 34000 to 425000 Btu/hr Nominal Capacity, Natural Gas, 24 VAC 60 Hz Coil, 1/4 in Male Quick-Connect Terminal, 32 to 175 deg F, 4-3/4 in H x 4-1/16 in W x 3-3/16 in D, Import