ALARM SYS IN/OUTDOOR HORN / LIGHT 115V 15A
Share
Product#ZOE 10-0126
MPN 10-0126
UPC053514036362
Description
The all new APak® alarm is more compact and easier to install. It is CSA approved in a NEMA 1 enclosure. Battery life is over 1 year from 2 AA batteries. Alarm may be used as AC only, DC only, or AC/DC applications. The APak® alarm system sounds a horn when a potentially threatening liquid level condition occurs. The horn can be silenced, but the alarm light remains on until the condition is remedied. A green "POWER ON" light indicates 120 V primary power to the alarm. A low battery chirp feature indicates when the battery should be replaced. A red "ALARM" light indicates a high-level condition.
Zoeller® A-Pak® II Alarm System, Single Phase High level, 88 dB Sound Level, 10 ft Detection, 115 VAC, 5 A, 20 ft Cord Length, Float Switch, Audible/Visual Indication, NEMA 4X Enclosure
Zoeller® A-Pak® II Alarm System, Single Phase High level, 88 dB Sound Level, 10 ft Detection, 115 VAC, 5 A, 20 ft Cord Length, Float Switch, Audible/Visual Indication, NEMA 4X Enclosure
ALARM SYS IN/OUTDOOR HORN / LIGHT 115V 15A
Share
Product#ZOE 10-0126
MPN 10-0126
UPC053514036362
- Brand: Zoeller®Amperage Rating: 5 ACord Length: 20 ftDetection Range: 10 ftEnclosure Type: NEMA 4XIndication Type: Audible/VisualSound Level: 88 dBSwitch Type: FloatType: Single Phase High levelVoltage Rating: 115 VAC
- NEMA 4X thermoplastic alarm panel (6 x 4 x 3 in)
- Horn and light warn of high liquid levels
- Test and silence switch
- Auxiliary, dry high level alarm contacts - 5 A
- Operates on separate circuit from pump
- Can be used with liquids to 140 deg F (60 deg C)
- Stand alone high water alarms and starter kits for single phase capacitor start/capacitor run pumps
- The all new APak® alarm is more compact and easier to install. It is CSA approved in a NEMA 1 enclosure. Battery life is over 1 year from 2 AA batteries. Alarm may be used as AC only, DC only, or AC/DC applications. The APak® alarm system sounds a horn when a potentially threatening liquid level condition occurs. The horn can be silenced, but the alarm light remains on until the condition is remedied. A green "POWER ON" light indicates 120 V primary power to the alarm. A low battery chirp feature indicates when the battery should be replaced. A red "ALARM" light indicates a high-level condition.
Zoeller® A-Pak® II Alarm System, Single Phase High level, 88 dB Sound Level, 10 ft Detection, 115 VAC, 5 A, 20 ft Cord Length, Float Switch, Audible/Visual Indication, NEMA 4X Enclosure