Product#AQSH BFP2-S
MPN BFP2-S
Description
The backflow enclosure shall be ASSE 1060-1996 (Class I,II, III) ASSE 1060-2006 (Class II, III) certified and shall provide freeze and vandal protection for backflow preventers installed outside and above ground. Materials shall be (.050/18 ga.) mill finished aluminum bonded to a unicellular, non-wicking polisocyanurate foam core insulation. Insulation shall be 1.5 in thick (R10) and have a heavy black reinforced fiber each side. Drain shall be insulated and sized to accommodate maximum discharge of the backflow preventer valve and remain closed except during discharge of the backflow valve. The enclosure shall have full access for testing and servicing of the backflow preventer with strategically placed lockable access panels. Enclosure shall be anchored to a concrete pad within the enclosure with masonry anchors.
AquaShield® Backflow Valve Heat Enclosure, Outdoor, Series: BFP, 43 in Length, 14 in Width, 28 in Height, 58 in L x 29 in W x 6 in H Mounting Pad, 120 VAC, 10, Aluminum Body
AquaShield® Backflow Valve Heat Enclosure, Outdoor, Series: BFP, 43 in Length, 14 in Width, 28 in Height, 58 in L x 29 in W x 6 in H Mounting Pad, 120 VAC, 10, Aluminum Body
- Brand: AquaShield®Body Material: AluminumHeight: 28 inLength: 43 inMounting Pad Size: 58 in L x 29 in W x 6 in HR Factor: 10Series: BFPType: OutdoorVoltage Rating: 120 VACWidth: 14 in
- Easy access
- Removable top and front panel
- Lockable for vandal protection
- Freeze Protection (-30 deg F) ASSE 1060- 1996 (Class I,II, III) ASSE 1060-2006 (Class II, III)
- No subassembly required
- Oversized drains at enclosure grade
- Structurally rigid insulation
- Simple installation
- Mounting hardware included
- 46 in L x 17 in W x 30 in H outside dimension
- 1-1/2 in thick wall/roof
- 60 watt, 1 phase heater
- The backflow enclosure shall be ASSE 1060-1996 (Class I,II, III) ASSE 1060-2006 (Class II, III) certified and shall provide freeze and vandal protection for backflow preventers installed outside and above ground. Materials shall be (.050/18 ga.) mill finished aluminum bonded to a unicellular, non-wicking polisocyanurate foam core insulation. Insulation shall be 1.5 in thick (R10) and have a heavy black reinforced fiber each side. Drain shall be insulated and sized to accommodate maximum discharge of the backflow preventer valve and remain closed except during discharge of the backflow valve. The enclosure shall have full access for testing and servicing of the backflow preventer with strategically placed lockable access panels. Enclosure shall be anchored to a concrete pad within the enclosure with masonry anchors.
AquaShield® Backflow Valve Heat Enclosure, Outdoor, Series: BFP, 43 in Length, 14 in Width, 28 in Height, 58 in L x 29 in W x 6 in H Mounting Pad, 120 VAC, 10, Aluminum Body